Cooling solutions for industrial enclosures: air vs liquid
Posted to News on 15th Dec 2020, 08:58

Cooling solutions for industrial enclosures: air vs liquid

In this article, Karl Lycett, climate control expert at Rittal, takes the heat out of the air/liquid cooling argument for industrial enclosures

Cooling solutions for industrial enclosures: air vs liquid

Almost without exception, industrial environments are hostile spaces for electrical equipment. Their components don’t react well to high levels of moisture, dust, and heat in the atmosphere and this sensitivity, in turn, can affect plant efficiency and could ultimately lower output and profitability.

But moisture, dust and heat don’t need to be a concern if users implement an effective climate control solution for equipment. The first step is to consider what constitutes suitable cooling to meet the needs of the design or installation, bearing in mind that these cooling needs may alter with any future changes to applications or usage within a facility.

It’s common for managers, when choosing a cooling solution, to default to air cooling using fans and filters because it’s familiar but while air cooling can be a viable solution, it also has its limitations which must be understood. This is clearly best done before it’s installed, otherwise one risks creating additional  problems further down the line.

Air Cooling

Air cooling is self-explanatory in that the cooling is achieved by passing cooler air from outside across the enclosure’s warmer internal components. However, this simplicity has its shortcomings which should be kept in mind. If at any point the temperature within the facility exceeds the maximum allowable temperature (setpoint) on inside of the enclosure, then no cooling will be possible. A good example of this is during the height of summer when the combination of lots of machinery and high ambient temperatures can cause temperature spikes within a factory. These will quickly lead to overheating componentry and the unexpected tripping of critical equipment. But this is only an issue if a factory is prone to surges in temperature. For many organisations, there is an acceptable level of general HVAC installed to ‘take the edge’ off the temperature, allowing air cooling to create a protective environment for the equipment within the enclosures.

Dust is a constant irritant within a factory and realistically it can never be fully removed. Even ‘cleanest’ industrial space will have a base level of detritus within the air which will then be drawn into enclosures if fans are employed. Unfortunately, this dust can get into wire connections or internal component fans and cause havoc over time, either preventing thermal exchange or blocking up and shorting wiring connections.

The best way to prevent dust issues arising is to add a suitable filter medium to the air cooling.  Filter mediums (or mats) ‘catch’ particulates before they enter the enclosure. The mats should be replaced on a regular basis to prevent a build-up of dirt which can then ‘choke’ the fan, preventing it from pulling sufficient cooling air into the enclosure.

Liquid Cooling

As mentioned earlier, it’s common to find traditional air-cooling methods are unviable or simply not especially effective in industrial spaces.  This can be due to factors such as the location or amount of the equipment involved, or it can be down to physical space restrictions,

Liquid cooling, however, is an option open to all, and one that is much more effective than air at removing waste heat and reducing the temperature within the enclosure. Liquid cooling, as the name suggests, uses chilled water to perform the cooling of the enclosure. An ‘Air to Air Heat Exchanger’ is mounted on the enclosure and connected to an industrial chiller. The chiller cools down heated water from the enclosure to a reasonable temperature before delivering it back to the heat exchanger.

The beauty of liquid cooling is that it is ‘active’ which means that you can make the internal temperature lower than that of the local environment. So even in the height of summer, with the factory in full swing, essential electrical equipment can be protected. Many industrial sites already have an operational chilled water supply to service other procedures and equipment. Where this is the case, it can be tapped off and used for enclosure cooling.

Liquid cooling requires hydraulic hoses (cold water in, hot water out) to be connected between the heat exchanger and the chiller. It’s therefore worth giving prior thought to both the enclosure placement and where to run the hoses to ensure the smooth commissioning and operation of the whole system.

Much like the air cooling, regular maintenance of the system is strongly recommended to ensure the cooling equipment can provide years of uninterrupted service. In summary, both solutions are valid but only in the right scenario.  However, choosing a cooling solution without first considering its operating environment is setting oneself up for less than perfect results. This in turn will have an impact on the overall effectiveness of a chosen cooling solution and the ongoing protection of your critical electrical equipment.


Rittal Ltd

Braithwell Way, Hellaby Industrial Estate
Hellaby
S66 8QY
UNITED KINGDOM

+44 (0)1709 704000

Bosch Rexroth Pilz Automation Ltd Procter Machine Safety ABSSAC Ltd Mechan Controls Ltd SICK (UK) LTD Phoenix Contact Ltd Machinesafe Compliance Ltd PI (Physik Instrumente) Ltd FATH Components Ltd Servo Components & Systems Ltd Heidenhain (GB) Ltd Euchner (UK) Leuze electronic Ltd Murrelektronik Ltd Dold Industries Ltd Rittal Ltd STOBER Drives Ltd HARTING Ltd Aerotech Ltd Smartscan Ltd WEG (UK) Ltd Spelsberg Els UK Ltd Micro Epsilon UK Limited AutomateUK AutomateUK Kawasaki Robotics (UK) Ltd M Buttkereit Ltd