New PKE motor-protective circuit-breaker with SmartWire-DT
Posted to News on 16th May 2012, 09:58

New PKE motor-protective circuit-breaker with SmartWire-DT

Eaton Electric is launching a PKE motor-protective circuit-breaker with SmartWire-DT communication for applications such as conveyor systems. Users can benefit from improved status indication and extended drive monitoring, even under tough operating conditions, and unnecessary outages can be prevented because overloads can be predicted and the motor switched off before it is tripped.

New PKE motor-protective circuit-breaker with SmartWire-DT

The overriding advantage of the PKE motor-protective circuit-breaker compared with conventional alternatives lies in the expanded drive monitoring. The diagnostic, status or overload messages show the actual flow of current and the status of the overload trip device. Moreover, the actual motor current can be continuously displayed and analysed via Eaton's SmartWire-DT communication system for switchgear without the need for any additional components.

Depending on the drive application, the following operating states can be differentiated: motor switched off, motor under load, motor no-load, motor operation, motor overload and motor fault. The separate load limits and the time response behavior can be individually programmed and adapted to all drive tasks. Emerging faults can be identified in good time thanks to the transmission of motor current and overload status. This enables the system operator to intervene in the production process before an undesirable interruption occurs. Of particular interest in this case is the option to operate the PKE as a motor protection relay. The motor-protective circuit-breaker is then not triggered in the event of overload; only the associated contactor is disconnected. Once the overload situation is rectified, the motor can be switched on again via the control unit without the maintenance personnel having to first reset the protection switch. This means that the PKE can be installed in locations that are not readily accessible.

Predicting trips and preventing downtime

Frozen elevating conveyors and typical belt conveyor scenarios when transporting coarse bulk material can only be insufficiently tracked in conventional drive control systems, as individual motors or belts at standstill are only indirectly interpreted via the switching states of the motor-protective circuit-breaker and power contactor. A hardware solution such as a speed sensor, load-shedding relay etc. is additionally required for a specific, reliable response. In the event of overload, the drive is immediately disconnected when the set current value is exceeded and a fault is signaled, thereby protecting the motor from being damaged. This results in unscheduled, time-consuming and costly downtime because conventional analogue I/O technology cannot image the current motor current as continuously and in such detail as the PKE, so the motor has to be shut down more often than necessary.

Follow the link for more information about the PKE motor-protective circuit-breaker with SmartWire-DT communication.


Eaton

Grimshaw Lane
Middleton
M24 1GQ
UNITED KINGDOM

+44 (0)161 655 8900

Bosch Rexroth Lenze Selection (a Division of Lenze Ltd) Mechan Controls Ltd Matara UK Ltd ABSSAC Ltd SICK (UK) LTD Spelsberg Els UK Ltd AutomateUK Servo Components & Systems Ltd Pilz Automation Ltd Machinesafe Compliance Ltd Phoenix Contact Ltd Moore International Ltd PI (Physik Instrumente) Ltd Leuze electronic Ltd AutomateUK Smartscan Ltd Lenze Selection (a Division of Lenze Ltd) Dold Industries Ltd Murrelektronik Ltd Procter Machine Safety Top Hex Ltd HARTING Ltd Euchner (UK) STOBER Drives Ltd Rittal Ltd FATH Components Ltd Aerotech Ltd Kawasaki Robotics (UK) Ltd Heidenhain (GB) Ltd maxon Group