Whitelegg Machines has supplied a Baker D12R surge tester to Bombardier for testing locomotive traction motors at its Crewe works.
Within the UK Bombardier has established a world-class engineering maintenance and repair site based at Crewe. Though railway vehicle construction ended at the Crewe site in 1991 with the completion of the Class 91 fleet for the East Coast Main Line, over 587 people are currently employed on, among others, component repair and overhaul of bogies, wheelsets and gearboxes; and electrical traction motors and control equipment.
The major thrust of the works is the repair and refurbishment of traction motors, both AC and DC, and their related wheel sets and bogies. Capacity is up to 70 motors per week. Within a locomotive there are four to six power wheel sets with one motor per set. Each motor is critical to the combined powertrain, with any failures leading to performance degradation and network operational issues.
Advanced component analysis and motor testing systems have been established and are contributing to significant increases in MTBF (mean time between failures) and unit availability.
Whitelegg Machines' testers play a significant part in these reliability improvements with the provision of a Baker D12R surge tester that is designed to maximise motor testing effectiveness in a lightweight, rugged format.
Bombardier uses the Baker units to carry out surge tests on DC motor fields, interpole coils and armatures to detect interturn shorts with motor types ranging from series to separately excited. The instrument is also used for testing AC traction motor stators, these being asynchronous induction motors.
The D12R provides winding resistance, DC flash and surge tests, with the ability to temporarily store up to ten sets of test results. Results can be printed out via an inkjet printer. An additional unit, the AT-101 bar-to-bar unit, is used in conjunction with the D12R to provide surge tests for DC armatures.
Surge testing is the only method of detecting weak turn-to-turn insulation (copper-to-copper) which will eventually lead to premature motor failure. The surge test works by sending high-voltage impulses into the winding to create a potential difference between the turns. The resultant sine waves should match each other closely when comparing like-for-like windings. When a weak area of insulation is present in a coil it allows an arc to occur between two turns, the inductance of the coil will change, causing the waveform to shift to the left, signifying a fault.
The Insulation Resistance (Meg-ohm) test is widely used throughout industry for testing motors, and many users take the results as a clear indication of motor/winding condition. However, since the Insulation Resistance (meg-ohm) test only considers the insulation between the windings and the frame (earth), it leaves part of the insulation system untested. Several studies over the years have proven that a high proportion of motor failures start as turn-to-turn weakness. Over time, this weakness worsens, eventually leading to a dead short to earth on the coil. In AC and DC motors, a dead short spells the end of the motor operation in service, and the motor would not be usable for service until the coil has been replaced by a motor overhaul, which requires the motor to be removed. Circulating currents cause excessive heat, which attack the weakest areas of insulation, such as the paper slot liners. When the slot liner fails, the motor will fail to earth.
Surge testing can be used to detect weak turn-to-turn insulation, prior to motor failure, thereby preventing in-service failure.
The Baker surge test unit has been used by Bombardier Crewe during normal motor overhaul to avoid in-service failures due to interturn shorts. Typically a failure of a motor in service under warranty can cost up to 50,000 to rectify, which includes the repair, removal and refitment costs incurred by the customer and any fines from Network Rail for blocking the line.
The surge tester has also been utilised as part of Crewe's motor insulation enhancement work. The Baker surge test is used to check that the interturn insulation is intact. This avoids the need for significant rework and avoids processing bad coils through the re-insulation process.